SCDF Fire Code: A Plain-English Guide for Businesses

SCDF Fire Code - A Plain-English Guide for Businesses

Fire safety in Singapore is governed by a law, a code and a set of certificates that are easy to mix up. If you own, occupy or manage a commercial or industrial building, you are expected to understand which of them apply to you. This guide explains the SCDF Fire Code in plain English: what it is, who it binds, the certificates involved, and what compliance actually looks like day to day.

Quick answer: the Fire Code is the Singapore Civil Defence Force’s Code of Practice for Fire Precautions in Buildings, currently the Fire Code 2023. It sits under the Fire Safety Act and sets how buildings must be designed and maintained for fire safety. Qualifying buildings also need a Fire Certificate, renewed on an ongoing basis.

The law and the code

Two documents sit at the top.

The Fire Safety Act is the legislation. It gives the Singapore Civil Defence Force its authority, creates the offences, and sets out duties for owners and occupiers.

The Fire Code is the technical code of practice made under it. The current edition is the Fire Code 2023. It is the reference that architects, engineers and fire safety professionals design against, covering means of escape, fire compartmentation, structural fire protection, fire-fighting systems, alarms and detection, smoke control, and access for fire service vehicles and crews.

You are not expected to design to the Fire Code yourself. That is the job of a Qualified Person. You are expected to know that it applies, and to maintain what it requires.

Who the Fire Code applies to

In practice, almost every non-domestic building in Singapore. Offices, factories, warehouses, workshops, shopping complexes, schools and healthcare premises all fall within scope, as do larger residential developments for their common areas.

The duty usually falls on the owner or occupier. If you lease a unit in an industrial building, you are typically responsible for fire safety within your demised premises, including keeping escape routes clear and equipment maintained, while the landlord or management corporation handles the building’s shared systems. Check your lease, because this is a common gap.

The certificates, and which is which

This is where most confusion sits.

  • Fire Safety Certificate (FSC): obtained through your Qualified Person after fire safety works are completed and before the premises are occupied or used. It confirms the works were carried out per the approved plans.
  • Temporary Fire Permit (TFP): allows occupation for a limited period where a full FSC is not yet in place.
  • Fire Certificate (FC): the ongoing one. Under the Fire Safety Act, owners or occupiers of qualifying public buildings must obtain and renew a Fire Certificate, demonstrating that the building’s fire safety systems are properly maintained and in working order.

The short version: the FSC is about how the building was built, the FC is about how it is being kept.

When you need a submission to SCDF

A fire safety plans submission, made through a Qualified Person, is needed when:

  • a new building is constructed
  • an existing building is renovated, or its use changes
  • fire protection systems are added, removed or modified

The submission comes before the work. Carrying out fire safety works without approval is an offence, and it commonly surfaces later when an FSC cannot be issued and occupation is delayed.

What compliance looks like day to day

What compliance looks like day to day

Beyond the paperwork, the recurring duties are unglamorous and they are what inspections actually find:

  • Keep means of escape clear. Corridors, staircases and final exits must not be used for storage. In warehouses this is the single most common failing.
  • Do not block or disable equipment. Hose reels, extinguishers, call points, sprinkler heads and riser inlets need clearance and must not be obstructed by racking or stock.
  • Maintain and service systems on schedule, with records kept. Detection, alarms, emergency lighting, sprinklers and pumps all have maintenance regimes.
  • Fire doors stay shut. Wedging a fire door open defeats compartmentation and is an easy citation.
  • Appoint a Fire Safety Manager where the premises require one, and run the drills and the emergency response plan.
  • Train your people. Equipment that nobody is confident using is not a control. Our guide on how to use a fire blanket is a good starting point for the simplest item on the wall.

Fire Safety Managers and emergency planning

Fire Safety Managers and emergency planning

Larger or higher-risk premises must appoint a Fire Safety Manager, a trained individual registered with the Singapore Civil Defence Force who is responsible for the day-to-day fire safety of the building. The role is not a formality. The FSM prepares and maintains the emergency response plan, runs fire drills, keeps the fire safety records, supervises the maintenance regime and leads the company emergency response team.

Whether your premises need an FSM depends on the building’s use and size. If you occupy part of a larger building, the FSM may sit with the landlord or the management corporation, but your own emergency procedures, evacuation arrangements and staff briefings remain yours.

What happens if you do not comply

Fire safety breaches in Singapore are criminal offences, not administrative ones. Carrying out fire safety works without approval, occupying premises without the required certificate, obstructing means of escape or failing to maintain fire safety systems can all attract enforcement, and penalties fall on the company and can reach individuals in charge.

There is a commercial edge too. An unresolved fire safety issue can delay occupation of a new or renovated unit, complicate a lease or sale, and create problems with insurers after an incident, since a policy will be examined against whether statutory obligations were met.

The newer risk the code now has to address

The Fire Code has had to catch up with lithium. Electric vehicles in car parks, energy storage systems on industrial sites, and the sheer number of battery-powered machines in a modern warehouse have introduced a hazard that conventional fire provision was not designed around.

A lithium battery fire behaves differently from the fires most equipment is rated for. It sustains its own reaction, releases toxic gas, and reignites. That is why containment, rather than extinguishing, is the accepted response, and why a lithium-grade fire blanket at a charging bay is now as sensible as an extinguisher by the door. Our guide to the classes of fire explains where battery fires sit in the classification, and why lithium batteries catch fire covers the mechanism.

Asia Green Fire Safe is the exclusive Fire Isolator dealer in Singapore, supplying lithium-grade blankets and the wider Fire Isolator containment range for warehouses, car parks and data centres.

Reviewing fire safety for a site with EV charging or battery storage? Talk to us about the containment equipment that belongs alongside your code-required provision.

Frequently asked questions about the SCDF Fire Code

What is the SCDF Fire Code?

The Fire Code is the Singapore Civil Defence Force’s Code of Practice for Fire Precautions in Buildings, currently the Fire Code 2023. It sets the technical requirements for how buildings must be designed and maintained for fire safety, covering escape routes, compartmentation, fire-fighting provision, alarms and access for the fire service. It sits under the Fire Safety Act.

Who needs a Fire Certificate in Singapore?

Under the Fire Safety Act, the owner or occupier of a public building that meets the prescribed criteria, which includes many offices, industrial buildings, shopping complexes and larger residential developments, must obtain and renew a Fire Certificate. It exists to prove the building’s fire safety systems are maintained and in working order.

What is the difference between a Fire Certificate and a Fire Safety Certificate?

They are different documents at different stages. A Fire Safety Certificate is obtained through your Qualified Person once fire safety works are completed, before the premises are occupied. A Fire Certificate is the ongoing compliance document for qualifying buildings in use, confirming the fire safety systems are maintained. Many businesses confuse the two.

When do I need to make a fire safety submission to SCDF?

A submission through a Qualified Person is required when a building is newly constructed, when it is renovated or changes use, and when fire protection systems are altered. Doing fire safety works without approval is an offence, so the QP submission comes before the work, not after.

Does the Fire Code cover EV charging and battery storage?

Yes. The 2023 code reflects newer risks, including provisions relevant to electric-vehicle charging and energy storage systems, which are now common in car parks and industrial premises. If you are installing chargers or battery storage, treat fire safety as part of the design rather than an afterthought.

Leave a Comment